Datasheet
View full specifications for Soracom’s removable IoT SIM card that breaks down to multiple form factors, and our embedded eSIM Connect that is attached directly onto your device at the factory.
SORACOM Air SIM card (plan01s) |
SORACOM Air Embedded SIM (plan01s) |
||
---|---|---|---|
Product code | SG001 | SGEIR01 | |
Form-factor | 3-in-1 (2FF/3FF/4FF) | MFF2 (Industrial Grade) | |
Application | USIM/SIM | USIM/SIM | |
Hardware | |||
Temperature Range | -25°C to +85°C (operation/storage) | -40°C to +105°C (in operation) -40°C to +125°C (in storage) |
|
Voltage | Supply voltage 1.62V to 3.3V (Class B/C) | Supply voltage 1.62V to 3.3V (Class B/C) | |
Non-Volatile Memory | 128 kilobytes NVM (non-volatile memory) available | Memory per profile Dynamic Memory Allocation Up to 400 kilobytes NVM (non-volatile memory) available NVM Endurance: Up to 500,000 Cycles/page @ 105°C, Max. Cycling: 16 million per | |
Data Retention | Up to 10 years at 85°C | Up to 15 years at 85°C | |
Other | M2M qualification (ETSI 102.671): NA ROHS compliance | Common Criteria EAL5+ Ruggedized Form Factor MFF2: TB-MA-HA-CA-VA-SA-RA-UB ROHS compliance | |
Software | |||
Java Card™ | 3.0.1 | 3.0.4 CE | |
Java Card™ Cryptographic APIs | CRC16, CRC32 DES, 3DES AES 128/256 bits | CRC16, CRC32 DES, 3DES AES 128/256 bits RSA up to 2048 bits SHA-1, SHA-2, SHA-3 ECC 128/256 | |
OTA | OTA over SMS (SCP80) OTA over HTTPs: Global Platform 2.2 amendment B (SCP81) | OTA over SMS (SCP80) OTA over HTTPs: Global Platform 2.2 amendment B (SCP81) | |
Other | 3GPP Release 11 |
Global Platform 2.2.1 Amendment A: Controlling Authority Scenario 2b Amendment C: Dynamic Memory Allocation Amendment D: SCP03 support Amendment E/F: Scenario 3 |
Soracom Air Embedded SIM Package Specifications
The SORACOM Air Embedded SIM (eSIM) is available in a MFF2 package which is compliant with ETSI TS 102.671 specifications.

Pin Layout
Pin Number | Contact Point | Signal | Purpose |
---|---|---|---|
1 | C5 | GND | Ground |
2 | C6 | NC | Reserved |
3 | C7 | I/O | Input or output for serial data |
4 | C8 | NC | Reserved |
5 | C4 | NC | Reserved |
6 | C3 | CLK | Clock signal input |
7 | C2 | RST | Reset signal input |
8 | C1 | VCC | Supply power input |
Each contact point conforms to ISO 7816-3 specification. Pins C4 and C8 are reserved and must remain isolated from other contact points (not physically or electrically connected).